TECHNICAL MANUAL
MMC 506:
DESCRIPTION:
Allows the technician to customise the tone cadence on a system-wide basis. There are ten tone cadences
available. The tone control of the cadence may be changed from interrupt tone to continuous tone. Some
DCS systems may require default settings to comply with local operating companies.
FEATURE KEYS
OPTIONS KEY
0
CONTINUOUS TONE
1
INTERRUPT TONE
PROGRAM KEYS
UP & DOWN
KEYPAD
SOFT KEYS
SPK
TONES
BUSY TONE
CONFM/BARGE
ERROR TONE
HOLD/CAMPON
RING TONE
TRSFER TONE
CO RINGBACK
CO DIAL TONE
ACTION
1.
Press TRSF 506
Display shows
2.
Press UP or DOWN key to select tone
Press LEFT soft key and advance to step 3
3.
Press UP or DOWN key to select tone
control
Press RIGHT soft key to advance to step 4
Press LEFT soft key to return to step 2
4.
Dial in new value for interrupt times
(must be four digits)
Press RIGHT soft key advances cursor
Press LEFT soft key retreats cursor back
If valid entry, system returns to step 2
5.
Press TRSF to store and exit
Press SPK to store and advance to next
MMC
Page 145 of 287 Updated I&M
Used to scroll through options
Used to enter selections
Move cursor left and right
Used to store data and advance to next MMC
DIAL TONE
MSGWAT TONE
DID RINGBACK
OR
OR
PROGRAMMING
Tone Cadence
DND/NO MORE
RGBACK TONE
CO BUSY
DISPLAY
BUSY TONE
INTERRUPT TONE
TRSFER TONE
INTERRUPT TONE
TRSFER TONE
INTERRUPT TONE
TRSFER TONE: 0100