TECHNICAL MANUAL
MMC 510:
DESCRIPTION:
Provides the ability to customise the SLT Message Wait LED cadence. There are two cadences available,
CONTINUOUS & INTERRUPT. The LED cadence control may be changed from interrupt to continuous. The
default setting of interrupt cadence is from 2000 to 2000.
The two options are as follows ;
CONTINUOUS
wait LED will be turned on continuously.
INTERRUPT
selection of the INTERUPT mode the cadence can be modified. The default cadence is 2 seconds on
and 2 seconds off.
FEATURE KEYS
OPTIONS KEY
0
CONTINUOUS
1
INTERRUPT
PROGRAM KEYS
UP & DOWN
KEYPAD
SOFT KEYS
SPK
ACTION
1.
Press TRSF 510
Display shows
2.
Press UP or DOWN key to select cadence
Press RIGHT soft key and advance to step 3
3.
Dial in new value for interrupt times
(must be four digits)
Press LEFT soft key retreats cursor back
If valid entry, system returns to step 2
4.
Press TRSF to store and exit
Press SPK to store and advance to next
MMC
DEFAULT DATA:
NOTE: All times are in milliseconds.
RELATED ITEMS: NONE
Page 151 of 287 Updated I&M
: When a Message is accepted, the SLT (that has Message Wait LED), the Message
: When a Message is accepted, the SLT the Message wait LED will filcker. On
Used to scroll through options
Used to enter selections
Move cursor left and right
Used to store data and advance to next MMC
OR
SLT Message Wait Cadence
DISPLAY
MW LED CADENCE
CONTINUOUS LED
MW LED CADENCE
INTERUPT LED
MW LED CADENCE
2000 2000
PROGRAMMING