11. HV-TR (transfer high-voltage output adjustment by condition)
DISP
COUNTER
ADJUST
FUNC
OPTION
TEST
Item
BODY
°C
Indicates the machine internal temperature measured
by the environment sensor.
BODY
%
Indicates the machine internal humidity measured by
the environment sensor.
BODY
g
Indicates the machine internal humidity absolute value
(g) measured by the environment sensor.
TRY-OFS-
Adjusts the transfer high-voltage output.
Y/M/C/K
ZONE-A/B/C
Indicates the machine internal humidity absolute value
(g) in the three ranges of A through C.
NOTE 1:
The setting of this item will return to the default value when the PCB is replaced or the RAM is cleared,
requiring input once again. Be sure to record any new setting you have made on the service label.
COPYRIGHT © 2001 CANON INC.
<M>
<S>
HV-TR-Y
1/4
BODY
xxx
˚C
BODY
xxx
%
BODY
xxx
g
TR-OFS-Y
xxxx
Description
CANON CLC1000/1000S/3100 REV.2 MAY 2001 PRINTED IN JAPAN (IMPRIME AU JAPON)
7. TROUBLESHOOTING IMAGE FAULTS/MALFUNCTIONS
<R>
<P>
READY
ZONE A
0.0g
ZONE B
6.9g
ZONE C
18.0g
<F>
READY
to
5.8g
see
2/4
to
18.0g
see
3/4
-----g
see
4/4
to
Remarks
Same as the reading
under 'DISPLAY > ANA-
LOG'.
Settings: –5 to +5
Unit = 1.0 µA
Standard: 0
If you have
changed the
settings of 'TRY-
OFS-Y/M/C/K',
check to make
sure that the
value of 'TR-#'
for each zone is
'0'; otherwise,
enter '0'.
7-243