5. Removing the Cleaner End Seal
1)
Remove the developing assembly/cleaning
unit from the copier (See chapter 4. IX.
PROCESS UNIT SYSTEM, A-2. Removing
the Developing Assembly/Cleaning Unit).
2)
Remove the cleaning blade.
3)
Remove one screw [1] each from the front and
rear; then, remove the cleaner end seal [2].
[1]
[2]
Figure 4-908B
6. Removing the Cleaning Assembly
Scoop-Up Sheet
1)
Remove the developing assembly/cleaning
unit from the copier (See chapter 4. IX.
PROCESS UNIT SYSTEM, A-2. Removing
the Developing Assembly/Cleaning Unit).
2)
Separate the developing assembly and the
cleaning unit.
3)
Remove the three screws [1], and remove the
cleaning assembly scoop-up sheet [2]
together with its support plate.
[2]
[1]
Figure 4-909B
COPYRIGHT © 2001 CANON INC.
[1]
[2]
[1]
[1]
CLC1000/1000S/3100 REV.2 MAY 2001 PRINTED IN JAPAN (IMPRIME AU JAPON)
4. MECHANICAL SYSTEM
C. Developing Assembly
1. Cleaning the Developing
Assembly Upper Cover
You may clean the developing assembly
upper cover if the copies have blots of toner or
when replacing the photosensitive drum.
1)
Slide out the process unit from the copier.
2)
Remove the developing assembly.
3)
Remove the four fixing screws [1], and
remove the developing assembly upper cover
[2].
Figure 4-901C
[1]
[2]
4-87