7. TROUBLESHOOTING IMAGE FAULTS/MALFUNCTIONS
21
Attaching the Timing Belt for
the Duplexing Unit Stacking
Assembly Paper Guide Plate
Install the gear [1] with the paper guide plate
fully open.
Install the timing belt [3] to the gear 1 and the
pulley [2].
Figure 7-265
22
Adjusting the Position of the
Separation Claw Solenoid

(SL15)

1) Place the delivery assembly upright.
2) Fix the solenoid in place where the distance
between the E-ring [3] and the resin washer [4]
is 3.5 ±0.5 mm when the plunger of the sole-
noid [1] is pulled by the spring [2].
[4]
[3]
Figure 7-266
7-34
COPYRIGHT © 2001 CANON INC.
[3]
[2]
[1]
[2]
[1]
23
Adjusting the Position of the
Upper Fixing Web Take-Up

Solenoid (SL3)

1) Keep the delivery assembly upright.
2) Fix the solenoid in place so that the vertical dis-
tance between the top end of the solenoid shaft
[2] and the top end of the solenoid lever [3] is
16.3 ±0.2 mm when the plunger of the solenoid
[1] is pushed.
[1]
24
When Replacing the Registra-
tion Roller Unit
You must make adjustments as follows when-
ever you have replaced the registration roller unit:
1) Replace the registration roller unit.
2) Make several copies of the Test Chart, and
check the leading edge margin, left/right mar-
gin, and for skew movement.
3) If the leading edge margin is not as specified,
make adjustments. (See II-A.)
4) If skew movement is noted, make adjustments
as instructed in the section that follows.