4. MECHANICAL SYSTEM
2)
Check to make sure that the marking [1] on
the lens assembly matches the marking [2] on
the lens mount (standard position).
[1]
[2]
Figure 4-608A
If the unit is not in standard position, loosen
the locking nut [3], and turn the lens assembly until
the distance to the end [4] of the lens assembly is
27.3 ±0.2 mm, i.e., where the markings match.
Figure 4-609A
4-62
COPYRIGHT © 2001 CANON INC.
[4]
[3]
CANON CLC1000/1000S/3100 REV.2 MAY 2001 PRINTED IN JAPAN (IMPRIME AU JAPON)
3)
Perform focusing adjustments by turning the
lens assembly once again according to the
values recorded on the label. For instance, if
the value is "+2/8," turn the lens assembly in
the positive direction (counterclockwise when
viewing from the end of the lens assembly)
over two notches.
Protrusion label
FS6-8028
Figure 4-610A
Figure 4-611A
5)
Tighten the locking nut [3], and fix the position
of the lens in place.
Positive direction