Table 6.3 Fault display and contents (Communication fault)

Code
Meaning
FMT
Input command is
Abnormal
different from the
Format.
normal format.
SUM
Part of the information
Check Sum
has been changed
Error.
during transmission.
MEM
Error in the EEPROM
Memory Fault.
parameter
Modification of the
WRE
unchangeable parameter
Rejection in
during running was
Running.
rejected.
Operation is being input
EEP
on EEPROM. (Other
EEPROM Busy.
input command is
ignored)
MOD
Invalid
Remote mode is not
Frequency /Run
selected.
command mode.
6. Troubleshooting
6-7
Cause
Corrective action
• The communications
command arrangement
is different from the
reguration protocol.
• The error caused by
noise, etc occurred to
the data on
communication.
• An error occurred in
the EEPROM.
• This command can
not be used in running..
• EEPROM is operating
at present.
Set the
• Invalid command in
appropriate
this mode.
mode.
Refer to B0.02.