• If B0.07 is set as 1 the motor starts automatically at power-up.
It may cause a serious accident. Thus, pay extra caution when
using automatic start operation.

5.3.2 System initialization

5.3.2.1 Controlling the inverter initialization : B1.01

Parameter
Name
Unit
No.
Inverter
B1.01
-
initialization
• B1.01 is used to initialize the parameters of the inverter .
When the inverter is initialized, all the changed parameters are deleted
and initialized to factory-setting values.
• Setting
Setting
Function
constant
1010
Complete initialization
1111
Partial initialization (exclude multi-functional I/O terminal setting)
5. Parameters
5-13
DANGER
Changeable
Setting
Factory
during
range
Setting
operation
0~9999
0000
X
MOSCON-E7 User's Manual
5-14

5.3.2.2 Setting and verifying the password : B1.02, B1.03

Parameter
Name
Unit
No.
B1.02
Check password
-
B1.03
Set password
-
• B1.02 is used to check and verify the password when a password has
been set in B1.03(i.e. B1.03 ≠ 0000).
• B1.03 is used to set the new password.
• When the new password is entered and saved in B1.03, not blinking
0000 is displayed immediately regardless of the input password.

5.3.3 Setting power capacity

5.3.3.1 Setting the inverter and motor capacity : B2.01, B2.02

Parameter
Name
Unit
No.
Power capacity of
B2.01
-
the inverter
Power capacity
B2.02
-
of the motor
• Parameter B2.01 is used to set the power capacity of the inverter.
• Parameter B2.02 is used to set the power capacity of the motor.
Capacity
(Motor &
0.4kW
0.75 kW
Inverter)
200V
20P4
20P7
400V
40P4
40P7
• The power capacity of the motor can not be set bigger than the
power capacity of the inverter.
• B2.01 and B2.02 can not be set to different voltage class.
Changeable
Setting
Factory
during
range
Setting
operation
0~9999
0000
X
0~9999
0000
X
Changeable
Setting
Factory
during
range
Setting
operation
20P4
-
X
~43P7
20P4
-
X
~43P7
1.5 kW
2.2 kW
3.7 kW
21P5
22P2
23P7
41P5
42P2
43P7
NOTE