Accel/Decel Time

Setting
Name
Unit
Range
F2.01
Accel Time 1
0.01sec
0.00~600.00
F2.02
Decel Time 1
0.01sec
0.00~600.00
F2.03
Accel Time 2
0.01sec
0.00~600.00
F2.04
Decel Time 2
0.01sec
0.00~600.00
Accel/Decel
F2.05
-
0~1
Time Base
S-Curve Accel/Decel Time
Setting
Name
Unit
Range
F3.01
S-Curve Time
0.01sec
0.00~2.50
S-parameter
DC Braking
Setting
Name
Unit
Range
DC Brake
S0.01
0.01Hz
0.00~10.00
Starting Frequency
DC Brake
S0.02
1%
0~100
Current
DC Braking Time
S0.03
0.1sec
0.0~25.0
at Start
DC Braking Time
S0.04
0.1sec
0.0~25.0
at Stop
Speed Search
Setting
Name
Unit
Range
Speed Search
S1.01
-
0~1
at Start
Speed Search
S1.02
0.01Hz
0.00~600.00
Start Frequency
Speed Search
S1.03
1%
0~200
Current
Speed Search
S1.04
0. 1sec
0~10.0
Deceleration Time
Appendix
A-5
Factory
Changeable
Page
Setting
During Operation
10.00
¡ Û
5-20
10.00
¡ Û
5-20
10.00
¡ Û
5-20
10.00
¡ Û
5-20
X
0
5-20
Factory
Changeable
Page
Setting
During Operation
0.20
¡ Û
5-21
Factory
Changeable
Page
Setting
During Operation
X
1.50
5-22
X
50
5-22
X
0.0
5-22
X
0.5
5-22
Factory
Changeable
Page
Setting
During Operation
X
0
5-23
X
0.00
5-23
X
100
5-23
X
2.0
5-23
MOSCON-E7 User's Manual
A-6
Dwell Operation
Setting
Name
Unit
Range
Dwell Frequency
S2.01
0.01Hz
0.00~600.0
at Start
Dwell Time
S2.02
0.01sec
0.00~25.00
at Start
Dwell Frequency
S2.03
0.01Hz
0.00~600.0
at Stop
Dwell Time
S2.04
0.01sec
0.00~25.00
at Stop
Energy Save Function
Setting
Name
Unit
Range
Energy Saving
S3.01
1%
0~100
Voltage Level
Energy Saving
S3.02
0.01Hz
0.00~600.00
Frequency Level
Slip Compensation
Setting
Name
Unit
Range
Slip Compensation
S4.01
1%
0~S4.03
Gain
Slip Compensation
S4.02
1msec
0~9999
Delay Time
Slip Compensation
S4.03
1%
0~250
Limit
Torque Compensation
Setting
Name
Unit
Range
Torque
Compensation
S5.01
1%
0~250
Gain
Torque
Compensation
S5.02
1msec
0~9999
Delay time
System function Compensation
Setting
Name
Unit
Range
Hunting
S6.01
%
0~100
Prevention Gain
Enable
S6.02
-
0~1
Brake Boosting
Current ripple
S6.03
restraint
-
0~1
(1 phase only)
Factory
Changeable
Page
Setting
During Operation
X
0.00
5-25
X
0.00
5-25
X
0.00
5-25
X
0.00
5-25
Factory
Changeable
Page
Setting
During Operation
X
80
5-26
X
0.00
5-26
Factory
Changeable
Page
Setting
During Operation
0
¡ Û
5-27
X
200
5-27
X
200
5-27
Factory
Changeable
Page
Setting
During Operation
X
100
5-29
X
20
5-29
Factory
Changeable
Page
Setting
During Operation
20
¡ Û
5-30
X
0
5-30
X
1
5-30

Advertisement