5.5.3 Dwell operation

5.5.3.1 Controlling the dwell operation : S2.01~S2.04
Parameter
Name
Unit
No.
Dwell Frequency
S2.01
0.01Hz
at Start
Dwell Time
S2.02
0.01Sec
at Start
Dwell Frequency
S2.03
0.01Hz
at Stop
Dwell Time
S2.04
0.01Sec
at Stop
• Dwell function is used to temporarily hold the output frequency when
starting and stopping a motor with heavy load.
Run Command
ON
Output
Frequency
S2.01
S2.02
Figure 5.10 Timing chart for dwell operation
5. Parameters
5-25
Changeable
Setting
Factory
during
range
Setting
operation
0.00
0.00
X
~600.0
0.00
0.00
X
~25.00
0.00
0.00
X
~600.0
0.00
0.00
X
~25.00
OFF
S2.03
Time
S2.04
MOSCON-E7 User's Manual
5-26

5.5.4 Energy saving operation

Energy can be saved by decreasing the output voltage of the inverter in
steady-state under a light load condition.
Do not use the energy-saving function in normal situation.
5.5.4.1 Setting the energy saving level : S3.01
Parameter
Name
Unit
Setting range
No.
Energy Saving
S3.01
1%
Voltage Level
• If S3.01=80, the output voltage in energy saving mode will be 80% of
the previous value.
5.5.4.2 Setting the energy-saving frequency : S3.02
Parameter
Name
Unit
No.
Energy Saving
S3.02
Frequency
0.01Hz
Level
• S3.02 sets the minimum frequency for the effective energy saving
operation
• Energy-saving command is enabled when output frequency is higher
than the energy-saving frequency and motor speed is within the "speed
match" range or energy saving command is triggered from a external
input terminal.
Changeable
Factory
during
Setting
operation
0~100
80