5.7 H-parameter : I/O Control functions

5.7.1 Multi-function contact input

5.7.1.1 Set input type of multi-function contact input: H0.01

Parameter
Name
Unit
No.
Select Terminal
H0.01
-
Input Type
• H0.01 is used to set the input type of each terminal.
•The definition of each bit in H0.01
bit7
bit6
bit5
bit4
Terminal
Terminal
H0.01
0
0
no. 6
no. 5
•Setting
Setting
Function
constant
0
Each bit is set as 'a' contact (NO)
1
Each bit is set as 'b' contact (NC)

5.7.1.2 Setting the function of contact input : H0.02~H0.05

Parameter
Name
Unit
No.
Function of
H0.02
-
Terminal3
Function of
H0.03
-
Terminal4
Function of
H0.04
-
Terminal5
Function of
H0.05
-
Terminal6
• Refer to the table on the next page for the function settings of the
multi-function input terminal.
• Note that H0.02~H0.05 should be different from each other.
5. Parameters
5-41
Changeable
Setting
Factory
during
range
Setting
operation
00~3F
(Hexa-
00
X
decimal)
bit3
bit2
bit1
bit0
Terminal
Terminal
Terminal
Terminal
no. 4
no. 3
no. 2
no. 1
Changeable
Setting
Factory
during
range
Setting
operation
0~19
1
X
0~19
2
X
0~19
3
X
0~19
6
X
MOSCON-E7 User's Manual
5-42
•Setting
Setting
Function
constant
Uses 3-wire operation when
0
3-Wire Sequence
operating with the external
terminal
1
External Fault
External fault signal input.
Resets the fault when turned
2
Fault Reset
on
3
Multi-step Speed 1
Runs in selecting the set
4
Multi-step Speed 2
speed(Using the binary code)
5
Multi-step Speed 3
Jog Frequency
Higher priority than multi-
6
Command Selection
step speed commands
ON: Clockwise run at jog
7
Reverse Jogging
frequency F0.09.
OFF: Counterclockwise run
8
Forward Jogging
at jog frequency F0.09.
Change the accel/decel rate
Accel/Decel Time
9
from F2.01/F2.02 to
Switching Command
F2.03/F2.04
ON: accel/decel stopped,
10
Holding Accel/Decel
frequency on hold
Blocks the output voltage of
External Base block
11
the inverter(Frequency on
Command
hold)
Frequency Up
Always set with the
12
Command
frequency down command.
Frequency Down
Always set with the
13
Command
frequency up command.
Uses the external current
Current Analog
14
analog command to the
Command Selection
command frequency
Valid in stopping only :
15

DC Braking

outputs DC current

Speed Search

Searches the speed to the
16
Command 1
output frequency
Speed Search
Searches the speed to the
17
Command 2
input frequency
Energy-Saving
ON: energy-saving control
18
Operation
set for S3.01, S3.02
Switches to the set
Remote → Local
19
speed/Run command in
Selection
local mode
Description
Reference
5-43
-
5-43
5-44
5-44
5-44
5-44
5-44
5-44
5-45
5-45
-
5-46
5-46
5-46
5-48
5-48
5-48
-
5-49