General Run and Transport Problems
Problem
Engine stops during operation (operator sitting on
seat).
Battery does not charge.
Groundsmaster 360
Possible Causes
Operator not in center of seat (seat switch is not
depressed).
Fuel tank is empty.
Machine is being operated on a slope with a low fuel
level.
The parking brake was engaged or the parking brake
sensor is faulty.
Fuse(s) is (are) faulty (other electrical components
most likely affected as well).
The engine temperature is excessive (above 240
o
115
C).
The seat switch is faulty.
The engine high temperature shutdown switch is faulty.
The engine run solenoid or fuel pump failed.
Wiring in the run circuit is faulty or disconnected (see
electrical schematic in Chapter 9 -- Foldout Drawings).
Loose or broken wire(s) (see electrical schematic in
Chapter 9 -- Foldout Drawings).
The engine alternator belt is loose or damaged.
The alternator warning lamp is faulty.
The alternator warning lamp wiring is loose, corroded
or damaged.
The fusible link connecting the engine starter motor to
the alternator is faulty.
The battery is faulty.
The alternator is faulty.