Toro Groundsmaster 360 Service Manual page 182

Hide thumbs Also See for Groundsmaster 360:
Table of Contents

Advertisement

Fault Code (Lamp Flashes)
1 -- 1
1 -- 2
1 -- 3
1 -- 4
1 -- 5
2 -- 1
2 -- 2
2 -- 3
2 -- 4
3 -- 1
3 -- 2
3 -- 3
3 -- 4
3 -- 5
4 -- 1
4 -- 2
4 -- 3
4 -- 4
Electrical System
High engine temp warning occurred (PTO was shutdown by controller)
High engine temp shutdown occurred (engine was shutdown by controller)
Low engine oil pressure occurred
Charging voltage was out of acceptable range
Upper fuse 3 (7.5 amp) for TEC outputs is faulty
Upper fuse 2 (7.5 amp) for TEC outputs is faulty
Upper fuse 1 (7.5 amp) for TEC outputs is faulty
No power available to TEC outputs (e.g. all fuses or main power relay faulty)
Current output to start relay was excessive (shorted or grounded)
Current output to run relay was excessive (shorted or grounded)
Current output to glow relay was excessive (shorted or grounded)
Current output to diagnostic light was excessive (shorted or grounded)
Current to PTO solenoid was excessive (shorted or grounded)
Current output to indicator light in steering selector switch circuit was excessive
Current output to deck raise circuit was excessive (shorted or grounded)
Current output to deck float circuit was excessive (shorted or grounded)
Current output to 4 wheel steer solenoid was excessive (shorted or grounded)
Page 5 - - 8
Fault Description
Engine alternator fault occurred
(shorted or grounded)
Groundsmaster 360