Advertisement

5 SEQUENCE INSTRUCTIONS FOR MOTION CPU

5.3.4 Timers: OUT T

Setting
data
X
Y
M
Device
Setting Value
[Instruction]
OUT T
OUT T
[Function]
Bit device
SM
F
T
C
D
(1) When the operation results up to the OUT instruction are ON, the timer coil goes
ON and the timer counts up to the value that has been set; when the time up
status (total numeric value is equal to or greater than the setting value), the
contact responds as follows:
A Contact
B Contact
(2) The contact responds as follows when the operation result up to the OUT
instruction is a change from ON to OFF:
Timer
Type of Timer
Coil
100ms timer
OFF
10ms timer
100ms retentive
OFF
Timer
(3) To clear the present value of a retentive timer and turn the contact OFF after time
up, use the RST instruction.
(4) A negative number ( -32768 to -1) cannot be set as the setting value for the timer.
If the setting value is 0, the timer will time out when the time the OUT instruction is
executed.
Usable device
Word device
W
T
C
SD
Z
Continuity
Non-continuity
Present Value
Prior to Time Up
of Timer
A Contact
Non-
0
continuity
Maintains the
Non-
present value
continuity
5 - 19
Constant
Pointer
Level
K
H
P
N
Setting value
(1 to 32767 is valid)
K50
T0
Setting value
(1 to 32767 is valid for
D1560
the data register details)
T0
After Time Up
B Contact
A Contact
Continuity
Continuity
Continuity
Continuity
Digit
desig-
Index
nation
: Usable
B Contact
Non-
continuity
Non-
continuity