Hitachi Relion 650 Series Technical Manual page 339

Hide thumbs Also See for Relion 650 Series:
Table of Contents

Advertisement

1MRK 511 557-UEN Rev. A
Name
OPAVGPRIL2
OPAVGPRIL3
CLAVGNOL1
CLAVGNOL2
CLAVGNOL3
CLAVGNCL1
CLAVGNCL2
CLAVGNCL3
CLAVGPRIL1
CLAVGPRIL2
CLAVGPRIL3
OPTIMNOL1
OPTIMNOL2
OPTIMNOL3
OPTIMNCL1
OPTIMNCL2
OPTIMNCL3
OPTIMPRIL1
OPTIMPRIL2
OPTIMPRIL3
CLTIMNOL1
CLTIMNOL2
CLTIMNOL3
CLTIMNCL1
CLTIMNCL2
CLTIMNCL3
Table continues on next page
Technical Manual
Type
Description
REAL
Average value of primary contact operating time till the last
accepted open operation for phaseL2
REAL
Average value of primary contact operating time till the last
accepted open operation for phaseL3
REAL
Average value of NO contact operating time till the last accepted
close operation for phaseL1
REAL
Average value of NO contact operating time till the last accepted
close operation for phaseL2
REAL
Average value of NO contact operating time till the last accepted
close operation for phaseL3
REAL
Average value of NC contact operating time till the last accepted
close operation for phaseL1
REAL
Average value of NC contact operating time till the last accepted
close operation for phaseL2
REAL
Average value of NC contact operating time till the last accepted
close operation for phaseL3
REAL
Average value of primary contact operating time till the last
accepted close operation for phaseL1
REAL
Average value of primary contact operating time till the last
accepted close operation for phaseL2
REAL
Average value of primary contact operating time till the last
accepted close operation for phaseL3
REAL
Final average value of NO contact operating time for open
operations for phaseL1
REAL
Final average value of NO contact operating time for open
operations for phaseL2
REAL
Final average value of NO contact operating time for open
operations for phaseL3
REAL
Final average value of NC contact operating time for open
operations for phaseL1
REAL
Final average value of NC contact operating time for open
operations for phaseL2
REAL
Final average value of NC contact operating time for open
operations for phaseL3
REAL
Final average value of primary contact operating time for open
operations for phaseL1
REAL
Final average value of primary contact operating time for open
operations for phaseL2
REAL
Final average value of primary contact operating time for open
operations for phaseL3
REAL
Final average value of NO contact operating time for close
operations for phaseL1
REAL
Final average value of NO contact operating time for close
operations for phaseL2
REAL
Final average value of NO contact operating time for close
operations for phaseL3
REAL
Final average value of NC contact operating time for close
operations for phaseL1
REAL
Final average value of NC contact operating time for close
operations for phaseL1
REAL
Final average value of NC contact operating time for close
operations for phaseL3
© 2021 Hitachi Energy. All rights reserved.
Section 12
Monitoring
333