11.5.9.2

Evaluation period

Options:
The parameter is used to set the period for the multiple actuation of the button. This enables the
user to switch several lamps at the same time. After the evaluation period has expired, all
telegrams are sent parallel via the activated communication objects.
For the device to recognize a multiple operation, the button operation must be carried out within
a defined time period (evaluation period). The time is started after the first actuation and
continues for the set evaluation period. A typical value for the evaluation period is 3 seconds.
Example (five objects):
The five objects "Sx: switching x actuation(s)" are connected with five actuator channels. If all
five channels are to be switched at the same time, the button must be pressed five times within
the evaluation period.
Product manual 2CKA001473B9488
Description of application and parameters
Setting option from 01.000 to 05.000 (ss.fff)