Device overview (rear side)
14
13
Fig. 3:
Device overview ABB SmartTouch
Po
Description
s.
[1]
Address of outdoor station
Setting of the address of the standard outdoor station.
[2]
Indoor station address
Setting the address of the indoor station.
X10: Setting the tens digits.
X1: Setting the ones digits.
X100 and X200: setting the hundreds digits
(must only be set for ABB-Welcome
[3]
Master/slave function
Only one indoor station in each apartment can be set as "Master" (ON=Master).
[4]
Terminal resistor
In video installations or mixed audio and video installations, the switch on the last device of
the connection must be set on "RC on" (ON=RC on).
[5]
KNX connection /ABB-free@home
[6]
Floor call connection
[7]
Connection of power input/bus connection
[8]
Temperature sensor connection
[9]
Binary input connection
[10
USB connection for firmware upgrade (only for factory use)
]
[11
Temperature sensor
]
[12
Loudspeaker
]
[13
Microphone
]
[14
SD card insertion position
]