2
ANALOG INPUT MODULE REPLACEMENT
Q68ADV
80µs/channel (When there is temperature drift compensation, the time calculated by
adding 160µs will be used regardless of the number of channels used.)
±15V
Between the I/O terminal and programmable controller power supply:
Between channels: non-isolated
Between the I/O terminal and programmable controller power supply:
Between the I/O terminal and programmable controller power supply:
500VDC, 20M or more
(I/O assignment: intelligent 16 points)
18-point terminal block
R1.25-3 (A solderless terminal with sleeve can not be used.)
0.64A
0.19kg
Q68ADI
±30mA
8 channels/module
Max. 100,000 times
photocoupler isolation
500VAC, for 1 minute
16 points
2
0.3 to 0.75mm
0.64A
0.19kg
: Compatible,
: Partial change required, ×: Incompatible
Compatibility
Precautions for replacement
The conversion speed of Q68ADV/I
to A616AD has become quick. And
then, on Q68ADV/I, the noise that did
not import on A616AD can be
imported as analog signal. In this
case, use the averaging
processing
function to remove the effect of noise.
Consider
replacement with multiple
Q68ADV/I.
I/O occupied points has changed to
16 points.
×
×
Wiring change is required.
×
2
- 6