ABB ACS5000 User Manual page 113

Water-cooled
Hide thumbs Also See for ACS5000:
Table of Contents

Advertisement

5. Remove the cable insulation at the point of entry (Fig. 6-18: 1).
If the outer cable screen is non-conductive, cut open the cable screen
in the middle of the stripped area (Fig. 6-18: 1). To turn the conductive
side inside out, pull the cable screen ends over the cable insulation
(Fig. 6-18: 2). Connect the screens ends with a continuous conducting
foil (Fig. 6-18: 3).
6. Pull the cable through the entry plate.
7. To prevent water from entering the cabinet, fit the grommet tightly
and seal any gaps with silicone.
8. If you had removed the entry plate, remount it and fasten it properly.
3BHS799208 E01 REV E
1
Figure 6-18 Preparing control cables for EMC plates
ACS5000 WATER-COOLED USER MANUAL
06 ELECTRICAL INSTALLATION
2
3
3
2
113/186