Note: To prevent accidental switching from remote control to local
control, see "9.2.5.2 Disabling / enabling local lock function" on page 156.
9.3

Operational commands

For instructions on how to start and stop the drive system from the CDP
control panel, see "8.7 Starting the drive" on page 129 and "8.8 Stopping
the drive" on page 133.
9.3.1

Setting the direction of rotation

Setting the direction of rotation from the CDP control panel is possible in:
• Local control mode (L)
• Remote control mode (R)
The arrow on the display indicates the direction of rotation:
• When the motor is running, the arrow indicates the actual direction.
• When the motor is not running, the arrow indicates the preselected
direction.
To set the direction of rotation, press the forward or backward key.
3BHS799208 E01 REV E
1 R
StateINU
MOTOR SP
POWER
ACT
PAR
FUNC
DRIVE
I
0
ACS5000 WATER-COOLED USER MANUAL
600.0 rpm
0
ReadyRun
0.00 rpm
0.0 kW
1 L ->
600.0 rpm
StateINU
ReadyRun
MOTOR SP
600.00 rpm
POWER
75.0 kW