Mitsubishi Electric MELSEC iQ-R Series Quick Start Manual page 41

Servo system, simple motion module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

3.
JOG start
Confirm that the workpiece moves in the "+" direction by forward command, and in the "-" direction by reverse command.
1. Select Axis 1 (X61).
2. Select either the JOG Forward Start req (X6E) or the JOG Reverse Start req (X6F).
Move the cursor to "JOG Forward Start req" or "JOG Reverse Start req", and double click it while pressing SHIFT key.
4.
Confirming JOG operation
Check the JOG operation in the Axis Monitor window.
Signals, such as Forward JOG start and Reverse JOG start, can be added from the Selectable Items in the Axis Monitor
window.
1. Click [Select Monitor Item] in the Axis Monitor window.
2. Select items to be added from the Selectable Item list.
3. Select "Cd.181 Forward JOG start", then click [Add].
4. Click [OK] to go back to the Monitor window.
2.
1.
3.
4.
3 POSITIONING CONTROL STARTUP
3.4 Operation Check
3
39

Advertisement

Table of Contents
loading