Testing - No Power To Circuit (With Module Out Of Circuit); Testing - Powered Circuit (With Module Out Of Circuit) - Toro 260 Series Service Manual

Hide thumbs Also See for 260 Series:
Table of Contents

Advertisement

Testing - No Power To Circuit (With Module Out of Circuit)

Meter Scale
Meter Probe Negative
Ohms
Pin 3
Diode*
Pin 3
Diode*
Pin 3
Diode*
Pin 3
Ohms
Pin 1
Ohms
Pin 2
*Note: If the multimeter does not have a diode test feature, this test can not be performed. This is not a problem if
powered tests are done. Powered tests must be performed to test relays (see table below).

Testing - Powered Circuit (With Module Out of Circuit)

Meter Scale
Ohms
Volts (Caution)
Volts (Caution)
*** Same as battery voltage
Note: A 12 volt battery is needed for this test. USE CAUTION WHEN MEASURING RESISTANCE WITH A
POWERED CIRCUIT. CONTACTING A VOLTAGE SOURCE WITH A METER IN OHMS POSITION CAN
SERIOUSLY DAMAGE THE METER.
260 Series Tractor Service Manual
Meter Probe Positive
Pin 5
Pin 6
Pin 1
Pin 4
Pin 4
Pin 4
Volt Meter
Neg Probe
Pos Probe
Pin 2
Pin 5
Pin 1
Pin 2
Pin 3
Pin 2
ELECTRICAL SYSTEMS
Meter Reading
Open (More than 100K ohms)
.5 to 1 Volt
.5 to 1 Volt
.5 to 1 Volt
350 to 400 ohms
Open (more the 100K ohms)
Battery
Neg Lead
Pos Lead
Pin 3
Pin 6
Pin 1
Pin 4
Pin 3
Pin 4
Meter Reading
< 10 Ohms
12 Volts***
12 Volts***
6 - 19

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

264-6264-h265-h267-h268-h269-h ... Show all

Table of Contents