This section describes the specifications of the USG as well as the cables and expansion
cards.
A.1 Cable
This section describes the PGND cable, power cable, configuration cable, Ethernet cable, and
optical fiber of the USG.
A.2 Optical Transceiver
GE and 10GE optical ports provided by the USG supports gigabit and 10-gigabit optical
transceivers, respectively.
A.3 Requirements for Installation Environment
This section describes the requirements for the USG installation environment, such as the
device position, humidity and temperature, cleanness, antistatic measures, lightning protection
measures, power supply, and anti-magnetic measures.
A.1 Cable
This section describes the PGND cable, power cable, configuration cable, Ethernet cable, and
optical fiber of the USG.
A.1.1 PGND Cable
This section describes the structure and specifications of the protection ground (PGND) cable
for you to ground the USG. Read this section before you make or purchase any PGND cables
for the USG.
The PGND cable is used in the following situations:
Issue 03 (2015-01-26)
The USG is installed inside the cabinet.
If the cabinet has been properly grounded, connect one end of the PGND cable to the
ground terminal of the USG and the other end to the ground port of the cabinet.
The USG is installed outside the cabinet.
Connect one end of the PGND cable to the ground terminal of the USG and the other end
to the ground bar in the equipment room.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
A
Appendix

A Appendix

244