8.1 Routine Maintenance

8.1.1 Monthly Maintenance

Table 8-1 Routine maintenance items
Item
Battery management
alarm
Cleanliness
Ambient temperature
monitoring
If the fault persists, contact Huawei technical support.

8.1.2 Quarterly Maintenance

Table 8-2 Routine maintenance items
Item
Battery management
parameter setting
iBAT connection
Issue 07 (2019-12-30)
Expected Result
No battery management alarm
is generated.
Wipe the battery surface using
a piece of white paper and the
paper does not turn black.
The ambient temperature
should be lower than 45° C.
Expected Result
Check that the battery
management parameters are
set based on site
requirements.
The iBAT is attached
firmly.
All iBAT cables are
Copyright © Huawei Technologies Co., Ltd.
8

Maintenance

Troubleshooting
Identify the cause of an alarm
based on the alarm information.
Remove dust from the battery
surface.
Find the cause of an abnormal
temperature.
Troubleshooting
Set parameters correctly.
Secure the iBAT again.