10
. Set time for "Timeout".
20 – 20000 ms (default: 5000)
When PV500 writes data in the specified address of PLC, it sends and receives commands and response
messages in the dedicated protocol between PV500 and PLC. The value set here is Timeout in the
message communication in this case.
If PLC sends no response in the time of Timeout, a Timeout error occurs.
11
. To notice to PLC that data output is complete, set "Data Output Completion Notice" to "Yes".
Specify an address to make the specified bit to "1" and the bit.
Output register: 0 - 99999:
Output bit: 0 - 15:
For Mitsubishi PLC, enter interface No. to output register. (Output bit is invalid.)
When using Ethernet interface
Refer to page 346 for details of network settings.
1.
Select "ENVIRONMENT" -> "Input/Output" -> "General Output" from the menu bar.
2.
Select "Ethernet" for "Destination".
3.
Set "Protocol" to "PLC Communication".
4.
Set "Scan Count", "Total Judgement",
"Judgement", and "Numerical Calculation"
to "Output" as necessary.
5.
Select a destination in "PLC Type".
6.
Specify the network setting of the selected "PLC
Type".
The network setting consists as listed below.
-
PV Station No.
-
IP Address
-
Port No.
-
Specify Station No.
-
Station No.
Items to be specified vary depending on the selected
PLC type. For the detail, refer to the network setting for
each PLC type in the next section.
7.
Make settings items after "Start Register".
Refer to "When using RS232C interface" (p.423) for details.
424
Be sure not to use the same register of the register for writing data.
Specifying "15" makes the highest order bit "1".