4.12.4 Selecting an Image Memory Save Condition
Inspected images can be saved in the image memory of PV500 when the judgement of the judging checker is
NG during the inspection. Select a judging checker to be a condition to output images.
This setting is available only when the condition of "Save Image Memory" is set to "NG judgment". These
conditions can be set from "Input/Output" of "ENVIRONMENT". (Refer to page 286.)
Selecting a Condition Expression of Saving Image
Memory
When Execution Mode is "Execute All"
1.
Select "Condition" in judgement output setting
window.
"Condition" setting window is displayed.
2.
Select "Condition" column of Save Img. Memory
or Image Output.
Select a judgment type to register.
[No]:
Not to save images.
[No Condition]:
Save all images without
selecting a condition
expression.
[JRC]:
Use a JRC (Internal) as a
condition to save images.
[JDC]:
Use a JRC (External) as a
condition to save images.
*Select "No Condition" to temporarily save all images regardless of a judgement condition when the image
saving condition is set to "NG Judgement" which is on the window of "Input/Output" of "ENVIRONMENT".
When the other conditions are selected than "NG Judgement", the setting of Judgment window is invalid.
(For the setting of "NG Judgement", refer to page 286.)
3.
Select "Checker No." column and enter a judgment number.
The status of the image memory save is displayed in the "Result" column.
"No" indicates that image save is not executed because the condition is not fulfilled.
4.
After setting is completed, press the CANCEL key.
Now you completed registering.
When "Output Conditions" under "ENVIRONMENT"
- "Input/Output" - "Image Output" is other than
"Judge. Per Cam."
When "Output Conditions" under
"ENVIRONMENT" - "Input/Output" - "Image
Output" is "Judge. Per Cam."
251