Panasonic PV500 User Manual page 367

Machine vision system imagechecker
Hide thumbs Also See for PV500:
Table of Contents

Advertisement

How to Wire
Connect them using the discrete wires supplied with the product. The special tool is required to connect the
wires.
Included connector and special tool
Included parts (Contact, housing and
semi-cover)
Special tool
Applicable wire
Size
Cross section area
2
AWG#22
0.3 mm
2
AWG#24
0.2 mm
1.
Bend the contact from the carrier, and set it in the pressure
welding tool.
2.
Insert the wire without removing its insulation until it stops,
and lightly grip the tool.
The wire is welded.
3.
Insert the welded wire into the housing.
4.
Attach the cover after inserting necessary wires.
Now you completed wiring.
To Rewire
You can pull out the contact using "contact puller" attached to the tool.
Product No.
AFP2801
AXY52000FP
Outer insulation diameter
f1.5 - f1.1
Rated current
3A
365