When using Individual trigger in "Use-Defined" execution
mode
Send
% S ?
? = 0 – 9 (Block No. to execute)
aa = 0 – 15:
Specifying a camera to capture an image
Specifies a value in decimal notation of 4-bit
data which specifying cameras; Bit 0 =
camera 0, Bit 1 = camera 1, Bit 2 = camera 2,
Bit 3 = camera 3
Bit3
-
Camera 3
Receive
% S
Error (ERROR 0 signal = ON)
% S
Error code
200
201
202
203
Example:
Starts an inspection specifying camera 1 and block No.9.
Send
Receive
Stop in continuous inspection, stop in execution of detect
trigger
% S BCC(76) CR
Send
No response
Receive
400
,
a
a
BCC
CR
Bit 2
Bit 1
-
-
Camera
Camera
Camera
2
1
$
BCC(52)
CR
!
Error code (3-digit)
Operation is stopped
"Camera Trigger" in "Camera" is set to "Individual".
Execution mode is NOT "User-Defined" in PV500.
The specified block is invalid. (The number which does not/ cannot exist
was specified.)
The 2nd to 4th command specified different block from of the 1st to 3rd
command.
The specified camera number is invalid.
-
No camera is connected.
-
The specified camera number is set to "Unused" in PV500.
-
Other number than 01 and 15 is specified.
A command specifying the camera which has already captured an image
is sent.
% S
9
,
% S $ 5
Example)
Specify Camera 2:
Bit3
Bit 2
0
1
Specify Cameras 1 and 3:
Bit3
Bit 2
Bit 0
-
1
0
0
BCC
CR
0
2
*
* CR
2 CR
Bit 1
Bit 0
® aa = 04
0
0
Bit 1
Bit 0
® aa = 10
1
0

Hide quick links: