Data That Can Be Used in Judgement
The data described below is that can be used in judgement expression. The symbols in parentheses are
displayed in operation expressions.
Checker - Position Adjustment (PAC) No.0-999
Item
Judgement
(JUDGE)
Base Judgement
Position Adjustment:
(BJUDGE)
No.0 (0)
Horizontal Base
Checker 0
No.1 (1)
Horizontal Base
Checker 1
(Center Detection)
No.2 (2)
Vertical Base Checker 2
No.3 (3)
Vertical Base Checker 3
(Center Detection)
Others
Item
Checker - Area Size
Adjustment (AUC) No.0-999
Checker - Line (LIC)
No.0-999
Checker - Binary
Window(BWC) No.0-999
Checker- Gray
Window(GWC) No.0-999
Checker - Binary
Edge(BEC) No.0-999
Checker - Gray Edge(GEC)
No.0-999
Checker- Feature Extraction
(FEC) No.0-999
Checker - Smart
Matching(SMC) No.0-999
Checker - Flaw
Detection(FWC) No.0-999
Position Adjustment:
Binary Edge
Feature
Extraction
Gray Edge
Matching
Smart Edge
(Circle)
Position Rotation
Adjustment:
Feature
Extraction
(Principal Axis
Angle)
360-degree
Matching
Base Checker 0
Judgement (JUDGE)
Judgement (JUDGE)
Pixel judgement (DJUDGE)
Object judgement (LJUDGE)
Judgement (JUDGE)
Judgement (JUDGE)
Judgement (JUDGE)
Judgement (JUDGE)
Judgement (JUDGE)
Judgement (JUDGE)
Judgement (JUDGE)
Position Rotation
Adjustment
Feature
Extraction
(2 checkers)
Matching
(2 checkers)
Rotation Adjustment
all
Base Checker 0
Base Checker 1
(Center Detection)
Base Checker 2
Base Checker 3
(Center Detection)
Condition for OK judgement
The specified object or edge is detected.
Pixel judgement and Object judgement are both
OK.
The number of pixels is within the Judgement
limits.
The number of objects is within the Judgement
limits.
Area value is within the OK Judgement limits.
Gray Average is within the OK Judgement limits.
The number of detected edges is within the OK
Judgement limits.
The number of detected objects is within the OK
Judgement limits.
The number of detected objects at the last phase
is equal to the maximum limitation of the number
of detected objects that was set at the last phase
of the sequence.
The number of detected flaws is within the OK
Judgement limits.
Condition for OK
judgement
The specified
object or edge is
detected.
The base checkers
can detect the
specified object or
edge.