Setting PLC Communication
Make setting to output data in PLC Communication.
When using RS-232C Interface
For the information of how to set Baud Rate and transmission format, refer to page 339.
1.
Select "ENVIRONMENT" > "Input/Output"
> "General Output" from the menu bar.
2.
Select "Serial (COM.0)" for "Destination".
3
. Set "Protocol" to "PLC Communication".
4
. Set "Scan Count", "Total Judgement",
"Judgement", and "Numerical
Calculation" to "Output" as necessary.
5
. Select a destination in "PLC Type".
6.
Press "Set" button of "PLC
Communication Setting".
The PLC communication setting menu is
displayed.
7
. Only when selecting "Panasonic: FP" for PLC Type, set "Specify Station No.".
Station Home (Default):
A command which specifies no station number is issued.
Example) %EE#WDD0001 × × × × ×
Specify Station No. (Station No.:1 – 99):
A command for a PLC with the specified station number is issued. Specify the same number of the station
number that is set for the PLC to communicate in "Station No.".
Example) When Station No. is 99
8
. In "Start Register", specify the first register number of the PLC that PV500 outputs data into.
0 to 99999 are available.
Not all addresses 0 to 99999 can be used in destination PLC. As the address allowed to be written by the
external device (PV500) varies depending on PLC, please make sure the address with the instruction
manual of PLC.
9
. Select 16-bit or 32-bit to output Scan count and Numerical calculation data in "Bit Width".
When output data exceeds the value which can be output in the selected Bit Width, "0" is output.
%99#WDD0001 × × × × ×