Setting Judgement Limits
Set a tolerance (Maximum and Minimum values) of the measured area. If the measured area is within the
tolerance, the object will be judged as "OK", if it is out of it, the object is judged as "NG".
1.
Select "Judgement Limits".
2.
Input the setting values for "OK Judge. Max." and "OK Judge. Min".
Enter the values in pixels.
3.
After inputting is completed, press the CANCEL key.
Running a Test
Confirm if the current settings perform an inspection properly.
1.
Press the TRIG key.
When a live image is displayed on the screen, PV captures a new image first and runs a test. When a
memory image is displayed, it runs a test using the current memory image without capturing any images.
Position adjustment and area size adjustment are also executed at the same time if they are used.
2.
Confirm the inspection result.
103