Mitsubishi Electric GOT2000 Series User Manual page 124

Graphic operation terminal
Hide thumbs Also See for GOT2000 Series:
Table of Contents

Advertisement

(3) Display example of operator management
(a)
Operator information management screen
(a)
No.
(a)
Operator Name
(b)
ID
(c)
Level
(d)
Update
(e)
Lock status
(f)
Operation keys
(g)
Drive in use
2 - 80
2.15 Operator Authentication
(b)
Item
Displays operator names.
Displays operator IDs.
Displays security levels for operators.
Displays the last updated dates of the operator information.
Displays the status whether the operator ID is locked.
Execution keys for each function
Displays and sets the storage location for imported and exported operator information.
To switch the drive, touch the key. (A: Built-in SD card/B: USB drive/E: USB drive/F: USB drive/G: USB
drive)
Only when the drive B, drive E, drive F, or drive G is installed on the GOT, the user can switch the drive.
(c)
(d)
(g)
Description
(e)
(f)

Advertisement

Table of Contents
loading

Table of Contents