Mmc 51 Tone/Ring Cadence - Samsung NX-308 Technical Manual

Nx-series
Hide thumbs Also See for NX-308:
Table of Contents

Advertisement

4Programming 1999.9.15 12:43 PM 페이지50
NX-SERIES
HYBRID KEY SYSTEM
MMC 51
This MMC is used to customize the tone cadence on a system-wide basis to any one of
the eight available selections.
Call Technical Support before changing any cadences, as some systems may require
default settings.
PROCEDURE
1. Press [TRANSFER] and dial 51
Display shows
2. Press [VOLUME (-) or (+)] to select a tone
3. Press [MUTE] or [MESSAGE] to set dial tone to
continuous or interrupted tone
Interrupt tone default data is: 1000 0250 1000 0250 ms
4. Dial new interrupt value for interrupt time,
(ON/OFF/ON/OFF) in 50 ms steps.
Each field is 3 digits (UNIT: 10 ms)
(e.g. 100/030/100/030 = 1000 ms [100×10]
'ON' and 300 ms [030×10] 'OFF' time)
5. Press [TRANSFER] to save and exit
DEFAULT DATA
TONE NAME
DIAL TONE
RING BACK TONE
BUSY TONE
TRSF TONE
ERROR TONE
CO LINE RING
STATION RING
RELATED MMC
NONE
TONE/RING CADENCE
DISPLAY
(DT)
(RBT)
(BST)
(TT)
(ERT)
(COR)
(STR)
PROGRAMMING SECTION
LCD DISPLAY
DATA
CONTINUOUS TONE
1000 2000 1000 2000 ms
0500 0500 0500 0500 ms
0200 0200 0200 0200 ms
0500 0250 0500 0250 ms
1000 3000 1000 3000 ms
0400 0200 0400 3000 ms

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nx-1232Nx-820

Table of Contents