4Programming 1999.9.15 12:43 PM 페이지49
NX-SERIES
HYBRID KEY SYSTEM
DISPLAY
DOR R OFF
(Door Ring
OFF time)
FIRST DGT
(First Digit
wait time)
HOOK OFF
(Hook OFF
time)
INTER DGT
(Inter Digit
duration)
MMC OUT
(MMC
session time)
OFF R INT
(Off hook
Ring Interval)
PAGE MAX
(Page duration) announcement.
RCAL DISC
(Recall
Disconnect
time)
RCAL RING
(Recall Ring
length)
RCAL WAIT
(Recall
Waiting time)
RCAL HOLD
(Recall Hold
time)
RCAL TRSF
(Recall
Transfer time)
SLT F MIN
(minimum SLT
Flash time)
SLT F MAX
(maximum SLT single-line station.
flash time)
SMDR PULS
(SMDR start
time for rotary LCD duration timer on the keysets.
dialing)
SMDR DTMF
(SMDR start
time for touchtone the LCD duration timer on the keysets.
dialing)
TRK DISC
DESCRIPTION
controls the duration of ringing at the door
ring destination before canceling
controls how long the system will wait for
dialing to begin before dropping the dial tone
and initiating an error tone.
controls the time before dial tone is sent to a
single-line station.
controls the grace period between dialing
valid digits before dropping the call and
returning the user back to an error tone.
controls the grace period between programming
actions while in a programming session, before
returning system to secure programming status.
controls the duration of time between ring
bursts to a user who has a camped-on call.
controls the allowed duration of a page
this is the time an attendant recall will
ring before being disconnected.
this is the length of time a transfer recall
will ring at a station before recalling the
operator
after a transferred call is recalling at the transferring 015SEC 0~250SEC
station and the station is busy, this timer will expire
and transfer the call to the operator.
This only applies to trunk calls.
determines the time calls can be left on hold
before recalling back to the holding station.
determines the time transferred calls ring
before recalling.
monitors the duration of a hookswitch flash to ensure that
the flash is valid and not a line transient or accidental
hookswitch bounce. It is the minimum time of single-line station.
maximum time of hookswitch flash of a
this grace period timer starts SMDR recording
for pulse (rotary) dialing and controls the
this grace period timers starts SMDR recording
for DTMF (Touch Tone) dialing and controls
controls the duration of an outside call
PROGRAMMING SECTION
MMC 50
D E F A U L T RANGE
030SEC 1~250SEC
025SEC 1~250SEC
0200MS
100~
2500MS
025SEC 1~250SEC
030SEC 1 0 ~ 2 5 0 S E C
015SEC 1~250SEC
020SEC 1~250SEC
002MIN 1~250MIN
015SEC 0~250SEC
045SEC 0~250SEC
045SEC 0~250SEC
0350MS
100~
2500MS
0800MS
100~
2500MS
030SEC 1~250SEC
015SEC 1~250SEC