4Programming 1999.9.15 12:43 PM 페이지48
NX-SERIES
HYBRID KEY SYSTEM
MMC 50
This MMC is used to adjust individual timers as necessary. All available timers are
described in the TABLE OF TIMERS AND VALUES.
NOTE: Seconds are shown as 'SEC', milliseconds as 'MS', and minutes as 'MIN'.
PROCEDURE
1. Press [TRANSFER] and dial 50
2. Press [VOLUME (-) or (+)] to select a timer
(e.g. ALM R DUR)
3. Enter new value using KEYPAD
4. Press [TRANSFER] to save and exit
DEFAULT DATA
See TABLE OF TIMERS AND VALUES
RELATED MMC
NONE
DISPLAY
ALM R INT
(Alarm ring
interval)
ALM R DUR
(Alarm ring
duration)
ARDL INT
(Auto Redial
interval)
ARDL RELS
(Auto Redial
release time)
CBACK NOA
(Callback no
answer time)
CO CO DIS
(CO to CO
disconnect
time)
DISA F DG
DISA I DG
DISA RING
DOOR RELS
(Door release
time)

TABLE OF TIMERS AND VALUES

DESCRIPTION
controls the time length between ring attempts
at a station when alarm reminder is set.
controls the length of ring cycle duration when
alarm reminder is set at a station.
controls the time between attempts after Auto
Redial is set 'ON' at a station.
controls the duration of a Ring No Answer
condition on an auto-redial number dialed
before auto redial is canceled.
controls the time before the callback is canceled
when a callback detects Ring No Answer
monitors the duration of an unsupervised
conference, external call forward, or DISA call.
upon expiring, both trunks are disconnected.
controls how long the system will wait for
dialing to begin the DISA incoming call.
controls the grace period between dialing valid
digits before dropping the call to DISA user.
controls no answer time for DISA internal calling.
controls the duration of time before the door
lock relay deactivates.
PROGRAMMING SECTION
SYSTEM TIMERS
LCD DISPLAY
DEFAULT
RANGE
025SEC
250SEC
010SEC
1~250SEC
045SEC
1~250SEC
045SEC
1~250SEC
030SEC
1~250SEC
010MIN
1~250MIN
025SEC
1~250SEC
025SEC
1~250SEC
030SEC
1~250SEC
1500MS
100~
2500MS