replacement. Contact technical support to resolve
this issue. If you continue, data corruption can
occur. Press X to continue or else power off the
system and replace the DIMM module and reboot.
If you have replaced the DIMM press X to continue
Single-bit ECC errors were detected during the
previous boot of the RAID controller. The DIMM on
the controller needs replacement. Contact
technical support to resolve this issue. Press X to
continue or else power off the system and replace
the DIMM module and reboot. If you have replaced
the DIMM press X to continue.
Single-bit overflow ECC errors were detected
during the previous boot of the RAID controller.
The DIMM on the controller needs replacement.
Contact technical support to resolve this issue. If
you continue, data corruption can occur. Press X to
continue or else power off the system and replace
the DIMM module and reboot. If you have replaced
the DIMM press X to continue
Single-bit overflow ECC errors were detected
during the previous boot of the controller. The
DIMM on the controller needs replacement. If you
continue, data corruption can occur. Press X to
continue or else power off the system and replace
the DIMM module and reboot. If you have replaced
the DIMM press X to continue
Multibit ECC errors were detected on the RAID
controller. If you continue, data corruption can
occur. Contact technical support to resolve this
issue. Press X to continue ore else power off the
system, replace the controller and reboot.
Multiple Single-bit ECC errors were detected during
the previous boot of the controller. The DIMM on
the controller needs replacement. If you continue,
data corruption can occur. Press X to continue or
else power off the system, replace the DIMM
module, and reboot. If you have replaced the
DIMM, press X to continue.
Single-bit overflow ECC errors were detected on
the RAID controller. If you continue, data
corruption can occur. Contact technical support to
resolve this issue. Press X to continue ore else
power off the system, replace the controller and
reboot.
Memory Error. Please check the SDRAM
connection. If problems persist contact Tech
Support.
Memory Error. Detected Unsupported RAID
Controller Memory. Contact Tech support.
4-94
Message
MegaRAID WebBIOS for storage expansion blades
Hitachi Compute Blade 500 Series EFI User's Guide
Description
When this message is displayed,
contact your reseller or call
maintenance personnel.
An error occurred on the disk array
controller memory. When this
message is displayed, contact your
reseller or call maintenance
personnel.