Note: When a drive group contains multiple disk arrays, specify the same
setting values on all disk arrays in the drive group.
Tip:
11
One of the following windows appears.
.
– When you select Write Through in the write policy setting, the
following window appears. Click Yes.
– When you select Always Write Back in the write policy setting, the
following window appears. Click Yes.
– When you select Write Back with BBU in the write policy setting, the
following window appears. Click Yes.
4-36
Menu items
capacity value for your RAID level. When specifying the maximum capacity
value, click Update Size.
When you configure a disk array to install an OS and put a value
larger than 2 TB, the OS can recognize up to 2 TB.
If you specify a larger disk array size than the maximum capacity,
Unacceptable size is displayed on the window and all the setting
items are initialized. You need to reset all items to the correct size.