5
Installation
Hicom 108/112/118 are compact, digital, Euro-ISDN-compatible telephone systems belonging
to the Hicom 100 E product family. They may consist of several components depending on the
version and on the requirements. These instructions are intended for Siemens field engineers
or the specialist contractors, who install, connect and commission the individual components
of the Hicom 108/112/118 system.
5.1
Selecting the most suitable location
Note the dimensions of and clearances required by the system and an expansion box
A mains socket must be within convenient reach
Do not install near sources of heat or electrical fields.
min. 10 cm
for opening
the MDF
min. 10 cm for
each expansion
(basic box only)
Figure 5-1
Location, dimensions and minimum clearances
Caution
!
The systems are only suitable for wall mounting.
A31003-K16-X001-3-7620, 07/99
Hicom 100 E Version 2.1, Service manual
Unit
37 cm
47 cm
30 cm
Selecting the most suitable location
Basic box and
20 cm
expansion box
P
min. 30 cm
S
U
max. 300 cm
U
P
S
max. 40 cm
150 cm
Installation
Printer
Battery box
Socket
(230 V∼)