Changing Port Configuration - Siemens Hicom 100 E Service Manual

Table of Contents

Advertisement

Programming guide
Programming ISDN lines
Example: the system extension number is 471147 (all ISDN lines in one route), up to SW 2.0.2
.
only
Input sequence
A
1 9 2
B
*
C
4 7 1 1 4 7
D
<OK>
E
<F8>
If an extension number is changed, you can enter the new number under point C or delete the
number by pressing the F3 key, Section 10.3.5.
10.1.1.2

Changing port configuration

Set the default entry "0" (automatic port recognition) to "1" to use the relevant port exclusively
as a Euro-ISDN trunk (point-to-point).
Example: ISDN port 1 is to be used exclusively as a point-to-point Euro trunk.
Input sequence
A
1 9 3
B
*
C
1
D
<OK>
E
<F8>
Other port types can also be specified, if necessary, by entering other values under point C.
The following values are possible:
0 = default ("automatic" as of 2.0.2.), 1 = P-P Euro trunk, 2 = QSIG network, 3 = CorNet
network (as of 2.0.2 Cornet 1), 4 = Euro bus, 5 = VN (FRA only), 6 = PMP Euro trunk (as of
2.0.2), 7 = CorNet 2 (as of 2.0.2)
10-2
Meaning
System extension number route 1
(select route 1–4 with "+" and "–" or
directly with "#")
Change input
System extension number
(without prefix or console code!)
Confirm input
Return to Start menu
Meaning
Port configuration Port 1
(select port 1–16 with "+" and "–" or
directly with "#")
Change input
P-P Euro-ISDN trunk (example)
Confirm input
Return to Start menu
Display
Route 1: –
Route 1
Route 1: 471147
Route 1: 471147
System administration
Display
Port 1: default
Port 1
Port 1: P-P Euro trunk
Port 1: P-P Euro trunk
System administration
A31003-K16-X001-3-7620
Hicom 100 E Version 2.1, Service manual
,
07/99