Beginning in privileged EXEC mode, follow these steps to enter the IP address of the VMPS:
Command
Step 1
configure terminal
Step 2
vmps server ipaddress primary
Step 3
vmps server ipaddress
Step 4
end
Step 5
show vmps
Step 6
copy running-config startup-config
The switch port that is connected to the VMPS server cannot be a dynamic access port. It can be either
Note
a static access port or a trunk port. See the
on page

Configuring Dynamic Access Ports on VMPS Clients

If you are configuring a port on a cluster member switch as a dynamic port, first use the rcommand
privileged EXEC command to log into the member switch.
Caution
Dynamic port VLAN membership is for end stations or hubs connected to end stations. Connecting
dynamic access ports to other switches can cause a loss of connectivity.
Beginning in privileged EXEC mode, follow these steps to configure a dynamic access port on a VMPS
client switch:
Command
Step 1
configure terminal
Step 2
interface interface-id
Step 3
switchport mode access
Step 4
switchport access vlan dynamic
Step 5
end
Step 6
show interfaces interface-id switchport
Step 7
copy running-config startup-config
To return an interface to its default configuration, use the default interface interface-id interface
configuration command. To return an interface to its default switchport mode (dynamic desirable), use
the no switchport mode interface configuration command. To reset the access mode to the default
VLAN for the switch, use the no switchport access interface configuration command.
78-14982-01
Purpose
Enter global configuration mode.
Enter the IP address of the switch acting as the primary VMPS server.
Enter the IP address of the switch acting as a secondary VMPS server.
You can enter up to three secondary server addresses.
Return to privileged EXEC mode.
Verify your entries in the VMPS Domain Server field of the display.
(Optional) Save your entries in the configuration file.
14-17.
Purpose
Enter global configuration mode.
Enter interface configuration mode and the switch port that is
connected to the end station.
Set the port to access mode.
Configure the port as eligible for dynamic VLAN membership.
The dynamic access port must be connected to an end station.
Return to privileged EXEC mode.
Verify your entries in the Operational Mode field of the display.
(Optional) Save your entries in the configuration file.
"Configuring an Ethernet Interface as a Trunk Port" section
Catalyst 2950 Desktop Switch Software Configuration Guide
Configuring VMPS
14-29

Advertisement

Table of Contents
loading

This manual is also suitable for:

Catalyst 2950

Table of Contents