Cisco 2950G 24 - Catalyst Switch Software Configuration Manual page 235

Desktop switch
Hide thumbs Also See for 2950G 24 - Catalyst Switch:
Table of Contents

Advertisement

Chapter 9
Configuring the Switch Interfaces
You must add a space between the interface numbers and the hyphen when using the
interface range command. For example, the command interface range fastethernet 0/1 - 5 is a
valid range; the command interface range fastethernet 0/1-5 is not a valid range.
The interface range command works only with VLAN interfaces that have been configured with
the interface vlan command (the show running-config privileged EXEC command output shows
the configured VLAN interfaces). VLAN interfaces that do not appear by using the show
running-config command cannot be used with the interface range command.
All interfaces in a range must be the same type; that is, all Fast Ethernet ports, all Gigabit Ethernet
ports, all EtherChannel ports, or VLAN interfaces.
This example shows how to use the interface range global configuration command to enable Fast
Ethernet interfaces 0/1 to 0/5:
Switch# configure terminal
Switch(config)# interface range fastethernet0/1 - 5
Switch(config-if-range)# no shutdown
Switch(config-if-range)#
*Oct
*Oct
*Oct
*Oct
*Oct
*Oct
changed state to up
*Oct
state to up
*Oct
state to up
This example shows how to use a comma to add different interface type strings to the range to enable all
Fast Ethernet interfaces in the range 0/1 to 0/3 and Gigabit Ethernet interfaces 0/1 and 0/2:
Switch# configure terminal
Switch(config)# interface range fastethernet0/1 - 3, gigabitethernet0/1 - 2
Switch(config-if-range)# no shutdown
Switch(config-if-range)#
*Oct
*Oct
*Oct
*Oct
*Oct
*Oct
changed state to up
*Oct
changed state to up
*Oct
changed state to up
If you enter multiple configuration commands while you are in interface-range mode, each command is
executed as it is entered. The commands are not batched together and executed after you exit
interface-range mode. If you exit interface-range configuration mode while the commands are being
executed, some commands might not be executed on all interfaces in the range. Wait until the command
prompt reappears before exiting interface-range configuration mode.
78-14982-01
gigabitethernet slot/{first port} - {last port}, where slot is 0
port-channel port-channel-number - port-channel-number, where port-channel-number is
from 1 to 6
6 08:24:35: %LINK-3-UPDOWN: Interface FastEthernet0/1, changed state to up
6 08:24:35: %LINK-3-UPDOWN: Interface FastEthernet0/2, changed state to up
6 08:24:35: %LINK-3-UPDOWN: Interface FastEthernet0/3, changed state to up
6 08:24:35: %LINK-3-UPDOWN: Interface FastEthernet0/4, changed state to up
6 08:24:35: %LINK-3-UPDOWN: Interface FastEthernet0/5, changed state to up
6 08:24:36: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/05,
6 08:24:36: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/3, changed
6 08:24:36: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/4, changed
6 08:29:28: %LINK-3-UPDOWN: Interface FastEthernet0/1, changed state to up
6 08:29:28: %LINK-3-UPDOWN: Interface FastEthernet0/2, changed state to up
6 08:29:28: %LINK-3-UPDOWN: Interface FastEthernet0/3, changed state to up
6 08:29:28: %LINK-3-UPDOWN: Interface GigabitEthernet0/1, changed state to up
6 08:29:28: %LINK-3-UPDOWN: Interface GigabitEthernet0/2, changed state to up
6 08:29:29: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/ 1,
6 08:29:29: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/ 2,
6 08:29:29: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/ 3,
Catalyst 2950 Desktop Switch Software Configuration Guide
Using the Interface Command
9-7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Catalyst 2950

Table of Contents