How to Install, Connect, or Replace the EVM-IPVS-16A Network Module
Steps
To connect the EVM-IPVS-16A network module to the network, follow these steps:
Take the DB-37 end of the provided DB-37 to BNC video breakout cable, and connect it to the VIDEO
Step 1
connector on the EVM-IPVS-16A network module.
Figure 39-5
Equipment connected to outdoor cameras must be permanently grounded in accordance with national
Warning
and local codes. Statement 374
Connect the BNC ends of the video breakout cable to the cameras in your network. The cable ends are
Step 2
labeled with the corresponding port number (0-15).
After you have wired the provided terminal block connectors according to the pinout information
Step 3
provided in
EVM-IPVS-16A network module and tighten the screws using a small slotted screwdriver.
Cisco Network Modules Hardware Installation Guide
39-8
Wire the provided terminal block connectors. See the
section on page
39-6.
Connecting the Video Breakout Cable to the EVM-IPVS-16A Network Module
Table
39-4, connect the terminal block connectors to the terminal block on the
Chapter 39
Connecting Cisco Analog Video Gateway Network Modules
"Wiring the Terminal Block Connectors"