Cisco CISCO2650 - 2650 Router Hardware Installation Manual page 294

Network modules installation guide
Table of Contents

Advertisement

Connecting 4-Port Serial Interface Network Modules to the Network
The following control signals are part of the extended set, in addition to the basic set listed above, and
are used on Cisco Extended 12-in-1 cables:
Control signal support depends on the interface type. Not all of the control signals listed above are
Note
supported by every interface type.
The control signal names used in this document are the names commonly used in the industry for
Note
RS-232. Other interface types may use other names for the equivalent control signals.
The 4-port serial interface network module (NM-CEM-4SER) supports both Cisco 12-in-1 interface
cables and Cisco Extended 12-in-1 interface cables with user-defined end-connectors permitting
connection to either DTE or DCE interfaces.
Interfaces and DTE or DCE modes are defined by the type of cable connected to the network module.
Use the Cisco 12-in-1 cable for X.21 interfaces. The X.21 interface connector does not require an
Tip
additional DIN connector.
For information on using Cisco 12-in-1 cables with the 4-port serial interface network module, see
Table
For information on using Cisco Extended 12-in-1 cables with the 4-port serial interface network module,
see
module.
All serial interface types are available in DTE or DCE format: DTE requires a plug connector at the
customer premises equipment (CPE) end, and DCE requires a receptacle connector at the CPE end.
Serial Interface Data Rates and Distance Limitations
All serial signals are subject to distance limits, beyond which the signal degrades significantly or is
completely lost. Generally, the slower the data rate, the greater the distance the signal can travel.
Table 27-2
understand and compensate for potential electrical problems, you may get good results at speeds and
distances greater than those listed. For instance, the recommended maximum rate for V.35 is 2 Mbps,
but 4 Mbps is commonly used.
Table 27-2 Maximum Recommended Speeds and Distances for Each Serial Interface Type
Data Rate, bps
2400
4800
Cisco Network Modules Hardware Installation Guide
27-4
Remote Loop (RL)
Test Mode (TM)
Ring Indicator (RI)
27-3.
Figure 27-4
illustrates how to connect the Cisco 12-in-1 cable to the network module.
Table
27-4.
Figure 27-5
illustrates how to connect the Cisco Extended 12-in-1 cable to the network
lists maximum recommended speeds and distances for each serial interface type. If you
EIA/TIA-232 Distance
Feet
200
100
Chapter 27
Connecting Circuit Emulation Over IP Network Modules
EIA/TIA-449, -530, -530A, V.35, X.21 Distance
Meters
Feet
60
4100
30
2050
Meters
1250
625
OL-2485-20

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents