3. Select a sensitivity value, from 1 to 100 for each region. The higher the number, the higher
the motion detection sensitivity. It is recommended that you choose a sensitivity between
30 to 70. The default is 60.
4. Select a threshold value, from 1 to 100 for each region. The higher the number, the more
motion will be needed to trigger a motion event. It is recommended that you choose a
sensitivity between 5 to 50. The default is 5.
5. Click Remove All to delete all motion detection regions. Click Delete to delete the selected
motion detection region.
6. Click OK to save the configurations. Click Cancel to exit the setup without saving the
changes.

Configuring Video Tamper Settings

Setup
1.
Go to
2.
Configure the parameters.

Figure 7-4 Video Tamper

Table 7-2 Tamper Configurations

Parameter
Video Tamper
Defocus
Detection
Enable Tamper
Detection
Enable Defocus
Detection
54
Video Analytics
Video Detection
Function
When the percentage of the tampered image and the duration exceed
the configured values, an alarm will be triggered.
When the image is blurred, an alarm will be triggered. This function is
available on some select models.
Check to enable video tamper detection.
Check to enable defocus detection.
Defocus Detection is only supported by the following models:
Video Tamper.