Tamper Detection; Figure 4-31 Video Analytics Tab; Figure 4-32 Tamper Detection Settings On The Video Analytics Tab - Honeywell HCD5HIH Reference Manual

Equip series true day/night network box camera
Hide thumbs Also See for HCD5HIH:
Table of Contents

Advertisement

Tamper Detection

Document 800-07067V5 Rev A
07/2013
®
HCD5 equIP
Series True Day/Night Network Box Camera Reference Guide
Figure 4-31
Video Analytics Tab
Each setting has three threshold levels: high (80%), medium (50%) and low (30%). When
these thresholds are exceeded, camera tampering or motion is detected, and alarm
messages appear above the video display and alarm signals are sent to DVRs/NVRs (see
Figure
4-33).
Figure 4-32
Tamper Detection Settings on the Video Analytics Tab
Set the Blur Threshold. Blur
can be affected by elements
such as water, for example
Set the Blinding Threshold.
Blinding applies to obstacles in
front of the camera lens
Set the Scene Change
Threshold
There are three types of tamper detection in the Tamper Detection Setting tab on the Video
Analytics tab: blinding the camera, blurring the video display, and tampering with the
camera field of view. The user should note that when the following conditions are
applicable, the tamper detection features should be manually disabled to avoid raising false
alarms:
During the configuration of the video display
While text is overlaid on the video
If the video display becomes too dark
Each Tamper Detection
Setting provides 3
threshold levels: High
(80%), Medium (50%)
and Low (30%).
71