Honeywell Vocollect Talkman A700 Product Manual page 51

Hide thumbs Also See for Vocollect Talkman A700:
Table of Contents

Advertisement

Error Message
"Noise sampling procedure timed out."
"Operator load failed."
"Power-off error."
"Self test mode set, but no script file
found."
"Software error while changing task. Task
unchanged."
"Task load failed."
"Task not loaded. No task name available."
"Telnet client process failed to start."
"Telnet session manager failed to start."
"Telnet VT220 emulation process failed to
start."
"Unable to receive input data."
Solution
1. Sample noise again.
2. Reboot the device.
1. Go to an area of known good coverage.
2. Turn the device off and then turn it back on again.
3. Reboot the device.
4. Reload VoiceClient.
1. Power on the device.
2. Reboot the device.
Edit the task configuration file, taskname.vcf, and change the
line selftest=1 to selftest=0.
1. Go to an area of known good coverage.
2. Turn the device off and then turn it back on again.
3. Reload the task.
4. Reboot the device.
5. Reload VoiceClient.
1. Go to an area of known good coverage.
2. Turn the device off and then turn it back on again.
3. Reload the task.
4. Reboot the device.
5. Reload VoiceClient.
1. Reload the task.
2. Turn the device off and then turn it back on again.
3. Reboot the device.
4. Reload VoiceClient.
1. Turn the device off and then turn it back on again.
2. Reboot the device.
3. Reload VoiceClient.
1. Turn the device off and then turn it back on again.
2. Reboot the device.
3. Reload VoiceClient.
1. Turn the device off and then turn it back on again.
2. Reboot the device.
3. Reload VoiceClient.
1. Turn the device off and then turn it back on again.
Confidential: For informational use by Honeywell resellers and customers only
Troubleshooting Equipment Problems | 51