Troubleshoot Startup Problems
SCE 2000 Operational Status
The following table lists the operational states of the SCE 2000. The Status LED on the SCE 2000 Front Panel reflects
the current SCE 2000 operational status. The operational status can be displayed using CLI command show system
operation-status.
Table 9-1
SCE 2000
SCE 2000
Description
Operational
Status
Booting
Initial state after reset
Operational
SCE 2000 becomes operational after completing the following
process:
•
Boot is completed
•
Power self-tests are completed without failure
•
Platform configuration is applied
Warning
SCE 2000 is fully operational (as above) but one of the
following occurred:
•
Line ports (FE ports) to the link are down
•
Management port link is down
•
Temperature raised above threshold
•
Voltage not in required range
•
Fans problem
•
Power supply problem
•
Insufficient space on the disk
Note: If the condition that caused the SCE 2000 to be in
Warning state is resolved (for example, link is up) the SCE
2000 reverts to Operational state.
Failure
System is in Failure state after Boot due to one of the following
conditions:
•
Power on test failure
•
Three abnormal reboots in less than 20 minutes
•
Platform configured to enter Failure mode consequent to
failure-induced reboot (this is configurable using CLI
command)
Note: Depending on the cause of failure, the management
interface and the platform configuration may or may not be
active/available.
54
Operational States
Status LED State
Orange
Flashing green
Flashing orange
Red