Installation Notes for Catalyst 3750-E,

Power Supply Modules

This document provides the removal and installation procedures for the power supply modules used with
the Catalyst 3750-E, the Catalyst 3560-E switches, and the Cisco Redundant Power System 2300
(RPS 2300).
For more information about using the power supply modules with a switch or an RPS 2300, see the
Catalyst 3750-E and Catalyst 3560-E Switch Hardware Installation Guide and the Cisco RPS 2300
Hardware Installation Guide on Cisco.com.
For translations of the safety warnings that appear in this publication, see the Regulatory Compliance
and Safety Information for the Catalyst 3750-E and Catalyst 3560-E Switch or the Cisco RPS 2300
Hardware Installation Guide that shipped with the product and that are also available on Cisco.com.
Contents
This document includes these sections:
Corporate Headquarters:
Cisco Systems, Inc., 170 West Tasman Drive, San Jose, CA 95134-1706 USA
© 2006 Cisco Systems, Inc. All rights reserved.

Advertisement

Table of Contents
loading

Summary of Contents for Cisco CATALYST RPS 2300

  • Page 1: Table Of Contents

    For translations of the safety warnings that appear in this publication, see the Regulatory Compliance and Safety Information for the Catalyst 3750-E and Catalyst 3560-E Switch or the Cisco RPS 2300 Hardware Installation Guide that shipped with the product and that are also available on Cisco.com.
  • Page 2: Catalyst 3560-E Switches And Rps

    RPS 2300. For more information about which RPS 2300 power supply modules to use for specific switch support, see the Cisco Redundant Power System 2300 Hardware Installation Guide. Table 2...
  • Page 3 Product Overview Figure 1 Figure 3 show the power supply modules. Figure 1 1150-W AC Power Supply Module A C O K PS O K 1150-W AC power supply module AC power connector AC OK LED Cooling fans PS OK LED Extraction handle Captive screw Figure 2...
  • Page 4 Product Overview Figure 3 265-W DC Power Supply Module F R U C C D C IN 2 6 5 W P S O K IN P U T -3 6 to -7 /1 2A O U TP U 26 5W M /2 2A 265-W DC power supply module Captive screws...
  • Page 5: Power Supply Module Installation

    Power Supply Module Installation Power Supply Module Installation This section describes how to remove and install a new or replacement power supply module in Catalyst 3750-E and Catalyst 3560-E switches, or an RPS 2300. See these sections: Tools and Equipment, page 5 •...
  • Page 6 Power Supply Module Installation Do not reach into a vacant slot or chassis while you install or remove a module or a fan. Exposed Warning circuitry could constitute an energy hazard. Statement 206 Only trained and qualified personnel should be allowed to install, replace, or service this equipment. Warning Statement 1030 Do not work on the system or connect or disconnect cables during periods of lightning activity.
  • Page 7 Power Supply Module Installation Figure 5 Inserting an AC-Power Supply into an RPS 2300 100- 240 10-5 A AC OK DC OK 50-6 0 HZ 100- 240 10-5 A Ci sc o RP 50-6 0 HZ STD BY DC OU TP S 24 50 AC TIV E TEM P...
  • Page 8 Power Supply Module Installation Installing a DC-Power Supply (Only Catalyst 3750-E and 3560-E Switches) To connect the switch to a DC-input power source, follow these steps: Preparing for Installation, page 8 Grounding the Switch, page 9 Installing the DC Power Supply in the Switch, page 10 Wiring the DC-Input Power Source, page 11 An exposed wire lead from a DC-input power source can conduct harmful levels of electricity.
  • Page 9: Grounding The Switch

    Power Supply Module Installation Grounding the Switch Warning This equipment must be grounded. Never defeat the ground conductor or operate the equipment in the absence of a suitably installed ground conductor. Contact the appropriate electrical inspection authority or an electrician if you are uncertain that suitable grounding is available. Statement 1024 Warning When installing or replacing the unit, the ground connection must always be made first and disconnected last.
  • Page 10 Power Supply Module Installation Use the ground screw to attach the single-ground lug and wire assembly or the dual-ground adaptor to Step 5 the switch rear panel. Using a ratcheting torque screwdriver, torque the ground-lug screw to 60 lbf-in. (960 ozf-in.) (Figure 10).
  • Page 11 Power Supply Module Installation Use a Phillips screwdriver to loosen the two captive screws at the lower edge that secure the power Step 4 supply module to the switch chassis (Figure 11). Step 5 Remove the power supply module from the power slot by pulling on the extraction handle. Insert the new power supply into the power supply slot, and gently apply pressure while pushing the Step 6 module into the slot...
  • Page 12: Technical Specifications

    Technical Specifications Torque all terminal block screws to 5 lbf-in. (80 ozf-in.). Step 4 Replace the terminal block plastic safety cover, and torque the screw to 10 lbf-in. (160 ozf-in.). Step 5 Move the DC-power source circuit-breaker handles to the ON position. Step 6 Confirm that the power supply DC OK LED is green.
  • Page 13 Technical Specifications Table 5 AC-Power Supply Module Power Specifications (continued) Input current C3K-PWR-1150WAC:12–6 A C3K-PWR-750WAC: 10–5 A C3K-PWR-265WAC: 5–2.5 A Output ratings C3K-PWR-1150WAC: 12 V@25 A, –52 V @ 16.4 A C3K-PWR-750WAC: 12 V@25 A, –52 V @ 8.75 A C3K-PWR-265WAC: 12 V@22 A Total input BTU C3K-PWR-1150WAC: 4725 Btus per hour, 1385 W...
  • Page 14: Related Publications

    You can order printed copies of documents with a DOC-xxxxxx= number. For more information, see the “Obtaining Documentation” section on page These documents provide complete information about the switch and are available on Cisco.com: Regulatory Compliance and Safety Information for the Catalyst 3750-E and Catalyst 3560-E Switch •...
  • Page 15: Documentation Feedback

    The DVD enables you to access multiple versions of installation, configuration, and command guides for Cisco hardware and software products. With the DVD, you have access to the same HTML documentation that is found on the Cisco website without being connected to the Internet.
  • Page 16: Cisco Product Security Overview

    We encourage you to use Pretty Good Privacy (PGP) or a compatible product (for example, GnuPG) to encrypt any sensitive information that you send to Cisco. PSIRT can work with information that has been encrypted with PGP versions 2.x through 9.x.
  • Page 17: Obtaining Technical Assistance

    Cisco engineer. The TAC Service Request Tool is located at this URL: http://www.cisco.com/techsupport/servicerequest For S1 or S2 service requests, or if you do not have Internet access, contact the Cisco TAC by telephone. (S1 or S2 service requests are those in which your production network is down or severely degraded.) Cisco engineers are assigned immediately to S1 and S2 service requests to help keep your business operations running smoothly.
  • Page 18: Obtaining Additional Publications And Information

    Cisco products that are sold through channel partners. It is updated twice a year and includes the latest Cisco offerings. To order and find out more about the Cisco Product Quick Reference Guide, go to this URL: http://www.cisco.com/go/guide...
  • Page 19 Join a discussion at this URL: http://www.cisco.com/discuss/networking • World-class networking training is available from Cisco. You can view current offerings at this URL: http://www.cisco.com/en/US/learning/index.html Installation Notes for Catalyst 3750-E, Catalyst 3560-E Switches and RPS 2300 Power Supply Modules...
  • Page 20 CCVP, the Cisco Logo, and the Cisco Square Bridge logo are trademarks of Cisco Systems, Inc.; Changing the Way We Work, Live, Play, and Learn is a service mark of Cisco Systems, Inc.; and Access Registrar, Aironet, BPX, Catalyst, CCDA, CCDP, CCIE, CCIP, CCNA, CCNP, CCSP, Cisco,...

This manual is also suitable for:

Catalyst 3560-eCatalyst 3750-e2300

Table of Contents