Technical data

Mains
Input voltage U
connection
Input frequency
Connection to mains
Starting delay
Motor
Output voltage
connection
Continuous output
current
Starting current
Output frequency
Frequency resolution
Control
Control method
characteristics
Switching frequency
(see parameter 2.6.9)
Frequency reference
Analogue input
Panel reference
Field weakening point
Acceleration time
Deceleration time
Braking torque
Ambient operating
Ambient
conditions
temperature
Storage temperature
Relative humidity
Air quality:
-
-
Altitude
Vibration
EN50178/EN60068-2-6
Shock
EN50178, EN60068-2-27
Enclosure class
(Continues on next page)
TECHNICAL DATA
208...240V; 380...500V; 525...690V; –15%...+10%
in
45...66 Hz
Once per minute or less
2 s (FR4 to FR8); 5 s (FR9)
0—U
I
: Ambient temperature max. +50°C,
H
I
: Ambient temperature max. +40°C,
L
I
for 2 s every 20 s
S
0...320 Hz (standard); 7200 Hz (special software)
0.01 Hz (NXS); Application dependent (NXP)
Frequency control U/f
Open Loop Sensorless Vector Control
Closed Loop Vector Control (NXP only)
NXS2/NX_5:
NXS2:
NX_5:
NX_6:
Resolution 0.1% (10-bit), accuracy ±1%
Resolution 0.01 Hz
8...320 Hz
0.1...3000 sec
0.1...3000 sec
DC brake: 30% * T
FR4-FR9:
I
: –10°C (no frost)...+50°C
H
I
: –10°C (no frost)...+40°C
L
FR10-FR12 (IP21):
I
/I
H
NXP0820 6 : –10°C (no frost)...+35°C)
FR10 (IP54):
I
/I
H
–10°C (no frost)...+35°C)
–40°C...+70°C
0 to 95% RH, non-condensing, non-corrosive,
no dripping water
chemical vapours
IEC 721-3-3, unit in operation, class 3C2
mechanical particles
IEC 721-3-3, unit in operation, class 3S2
100% load capacity (no derating) up to 1,000 m
1-% derating for each 100m above 1,000m.
Max. altitudes: NXS2: 3,000m; NX_5 (380...400V): 3,000m;
NX_5 (415...500): 2,000m; NX_6: 2,000m
5...150 Hz
Displacement amplitude 1 mm (peak) at 5...15.8 Hz (FR4...9)
Max acceleration amplitude 1 G at 15.8...150 Hz (FR4...FR9)
Displacement amplitude 0.25 mm (peak) at 5-31 Hz (FR10...12)
Max acceleration amplitude 0.25 G at 31...150 Hz (FR10...12)
UPS Drop Test (for applicable UPS weights)
Storage and shipping: max 15 G, 11 ms (in package)
IP21/NEMA1 standard in entire kW/HP range
IP54/NEMA12 option in FR4 to FR10
Note! Keypad required for IP54/NEMA12
in
overload 1.5 x I
(1 min./10 min.)
H
overload 1.1 x I
(1 min./10 min.)
L
Up to NX_0061: 1...16 kHz; Default: 10 kHz
NX_0075 and greater: 1...10 kHz; Def: 3.6 kHz
NX_0072 and greater: 1...6 kHz; Def: 3.6 kHz
1...6 kHz; Default: 1.5 kHz
(without brake option)
N
: –10°C (no frost)...+40°C (except NX_0461 6, NX_0590 6,
L
: –10°C (no frost)...+40°C (except NX_0520 5, NX_0416 6:
L
4
23(110)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents