4
18(110)
4.2

Power ratings

4.2.1
NX_5 – Mains voltage 380—500 V
High overload = Max current IS, 2 sec/20 sec, 150% overloadability, 1 min/10 min
Low overload = Max current IS, 2 sec/20 sec, 110% overloadability, 1 min/10 min
All sizes are available as IP21/NEMA1 Sizes FR4 to FR10 are additionally available as IP54/NEMA12.
FR12 is available only as NXP.
Mains voltage 380-500 V, 50/60 Hz, 3~
Frequency
converter
Low
type
Rated
continuous
current I
L
(A)
NX 0003 5
3.3
NX 0004 5
4.3
NX 0005 5
5.6
NX 0007 5
7.6
NX 0009 5
9
NX 0012 5
12
NX 0016 5
16
NX 0022 5
23
NX 0031 5
31
NX 0038 5
38
NX 0045 5
46
NX 0061 5
61
NX 0072 5
72
NX 0087 5
87
NX 0105 5
105
NX 0140 5
140
NX 0168 5
170
NX 0205 5
205
NX 0261 5
261
NX 0300 5
300
NX 0385 5
385
NX 0460 5
460
NX 0520 5
520
NX 0590 5
590
NX 0650 5
650
NX 0730 5
730
NX 0820 5
820
NX 0920 5
920
NX 1030 5
1030
Table 4-1. Power ratings and dimensions of NX, supply voltage 380—500V.
Note: The rated currents in given ambient temperatures are achieved only when the switching frequency is equal to
or less than the factory default.
Note: The rated currents for FR10 to FR12 are valid at an ambient temperature of 40°C (except for 0520 5: rated
currents valid at an ambient temperature of 35°C).
TECHNICAL DATA
Following continuous operation at rated output current, 150 % rated output current (IH)
for 1 min, followed by a period of load current less than rated current, and of such
duration that the r.m.s output current, over the duty cycle, does not exceed rated output
current (IH)
Following continuous operation at rated output current, 110% rated output current (IL)
for 1 min, followed by a period of load current less than rated current, and of such
duration that the r.m.s output current, over the duty cycle, does not exceed rated output
current (IL)
Loadability
High
10%
Rated
50%
overload
continuous
overload
current
current I
current
H
(A)
(A)
(A)
3.6
2.2
3.3
4.7
3.3
5.0
6.2
4.3
6.5
8.4
5.6
8.4
9.9
7.6
11.4
13.2
9
13.5
17.6
12
18.0
25.3
16
24.0
34
23
35
42
31
47
51
38
57
67
46
69
79
61
92
96
72
108
116
87
131
154
105
158
187
140
210
226
170
255
287
205
308
330
245
368
424
300
450
506
385
578
572
460
690
649
520
780
715
590
885
803
650
975
902
730
1095
1012
820
1230
1133
920
1380
Motor shaft power
380V supply
Max
10%
50%
current
overload
overload
overload
I
40°C
50°C
S
P(kW)
P(kW)
P(kW)
4.4
1.1
0.75
6.2
1.5
1.1
8.6
2.2
1.5
10.8
3
2.2
14
4
3
18
5.5
4
24
7.5
5.5
32
11
7.5
46
15
11
62
18.5
15
76
22
18.5
92
30
22
122
37
30
144
45
37
174
55
45
210
75
55
280
90
75
336
110
90
349
132
110
444
160
132
540
200
160
693
250
200
828
250
250
936
315
250
1062
355
315
1170
400
355
1314
450
400
1476
500
450
1656
500
500
500V supply
10%
50%
Frame
overload
40°C
50°C
P(kW)
1.5
1.1
FR4
2.2
1.5
FR4
3
2.2
FR4
4
3
FR4
5.5
4
FR4
7.5
5.5
FR4
11
7.5
FR5
15
11
FR5
18.5
15
FR5
22
18.5
FR6
195x519x237/18.5
30
22
FR6
195x519x237/18.5
37
30
FR6
195x519x237/18.5
45
37
FR7
55
45
FR7
75
55
FR7
90
75
FR8
110
90
FR8
132
110
FR8
160
132
FR9
480x1150x362/146
200
160
FR9
480x1150x362/146
250
200
FR10
595x2018x602/340
315
250
FR10
595x2018x602/340
355
315
FR10
595x2018x602/340
400
355
FR11
794x2018x602/470
450
400
FR11
794x2018x602/470
500
450
FR11
794x2018x602/470
500
500
FR12
1210x2017x602/600
630
500
FR12
1210x2017x602/600
710
630
FR12
1210x2017x602/600
Dimensions and
weight
WxHxD/kg
128x292x190/5
128x292x190/5
128x292x190/5
128x292x190/5
128x292x190/5
128x292x190/5
144x391x214/8.1
144x391x214/8.1
144x391x214/8.1
237x591x257/35
237x591x257/35
237x591x257/35
291x758x344/58
291x758x344/58
291x758x344/58

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents